Infant Radiant Warmer, Open Care System
NIC721 - Infant Radiant Warmer with Fixed Baby Cradle & Drawers (Premium) with Microprocessor based temprature controller with 2 modes Skin / Manual mode
These are mobile Warmer mounted on wheels with fixed baby cradle, lower shelf and 3 drawers storage Cabinet.
Technical Specification Heater Box Halogen Examination Lamp (12 Volts, 50 Watts) To provide accurate assessment of Infant colour and sufficient illumination during procedures. Baby Tray (Stainless Steel) Control Modes: Skin / Manual. Range: Skin control: 34 to 38 ˚C Resolution: 0.1˚ C Accuracy: ± 0.2˚ C Display: 1” bright skin & air temp.(7 segment LED) % of heater output (bar graph)" Status: On LED Timer: Timer / APGAR Manual mode: Time Programmable Heater output settable Over temp. cut-off Alarm: Auto audio alarm mute, Mute time programmable Safety alarms: ON LED The mentioned are default limit, can be set or alter as per requirement:
|
NIC720 - Infant Radiant Warmer with Fixed Baby Cradle & Drawers (Premium) with Microprocessor based temprature controller with 3 modes Skin / Air / Manual mode
These are mobile Warmer mounted on wheels with fixed baby cradle, lower shelf and 3 drawers storage Cabinet.
Technical Specification Heater Box To provide accurate assessment of Infant colour and sufficient illumination during procedures. Baby Tray (Stainless Steel) Control Modes: Skin / Air / Manual. Range:Skin control: 34 to 38 ˚C Air control: Room temp. to 39˚ C" Resolution: 0.1˚ C Accuracy: ± 0.2˚ C Display: 1” bright skin & air temp.(7 segment LED) % of heater output (bar graph)" Status: On LED Timer: Timer / APGAR Timer/Baby Attend Manual mode: Time Programmable Heater output settable Over temp. cut-off Alarm: Auto audio alarm mute, Mute time programmable Safety alarms: ON LED The mentioned are default limit, can be set or alter as per requirement:
- Skin Low 0.5˚C - Under range(<34˚C) - Over range(>38˚C) - Low 3.0˚C - Over range |
NIC731 - Infant Radiant Warmer with Fixed Baby Cradle (Premium) with Microprocessor based temprature controller with 2 modes Skin / Manual mode
This is mobile Warmer mounted on wheels with fixed baby cradle.
Mechanical Specification Heater Box To provide accurate assessment of Infant colour and sufficient illumination during procedures. Baby Tray (Stainless Steel) Control Modes: Skin / Manual. Range: Skin control: 34 to 38 ˚C Resolution: 0.1˚ C Accuracy: ± 0.2˚ C Display: 1” bright skin & air temp.(7 segment LED) % of heater output (bar graph)" Status: On LED Timer: Timer / APGAR Manual mode: Time Programmable Heater output settable Over temp. cut-off Alarm: Auto audio alarm mute, Mute time programmable Safety alarms: ON LED The mentioned are default limit, can be set or alter as per requirement:
|
NIC730 - Infant Radiant Warmer with Fixed Baby Cradle (Premium) with Microprocessor based temprature controller with 3 modes Skin / Air / Manual mode
This is mobile Warmer mounted on wheels with fixed baby cradle.
Mechanical Specification Heater Box To provide accurate assessment of Infant colour and sufficient illumination during procedures. Baby Tray (Stainless Steel) Control Modes: Skin / Air / Manual. Range:Skin control: 34 to 38 ˚C Air control: Room temp. to 39˚ C" Resolution: 0.1˚ C Accuracy: ± 0.2˚ C Display: 1” bright skin & air temp.(7 segment LED) % of heater output (bar graph)" Status: On LED Timer: Timer / APGAR Timer/Baby Attend Manual mode: Time Programmable Heater output settable Over temp. cut-off Alarm: Auto audio alarm mute, Mute time programmable Safety alarms: ON LED The mentioned are default limit, can be set or alter as per requirement:
- Skin Low 0.5˚C - Under range (<34˚C) - Over range (>38˚C) - Low 3.0˚C - Over range |
NIC681 - Radiant Warmer Stand / Radiant Overhead Lamp (Premium) with Microprocessor based temprature controller with 2 modes Skin / Manual mode
This is mobile Warmer mounted on wheels with fixed baby cradle.
Mechanical Specification Heater Box Heater Box To provide accurate assessment of Infant colour and sufficient illumination during procedures. Essential Attachments Control Modes: Skin / Manual. Range: Skin control: 34 to 38 ˚C Resolution: 0.1˚ C Accuracy: ± 0.2˚ C Display: 1” bright skin & air temp.(7 segment LED) % of heater output (bar graph)" Status: On LED Timer: Timer / APGAR Manual mode: Time Programmable Heater output settable Over temp. cut-off Alarm: Auto audio alarm mute, Mute time programmable Safety alarms: ON LED The mentioned are default limit, can be set or alter as per requirement:
|
NIC680 - Radiant Warmer Stand / Radiant Overhead Lamp (Premium) with Microprocessor based temperature controller with 3 modes Skin / Air / Manual mode
This is mobile Warmer mounted on wheels with fixed baby cradle.
Mechanical Specification Heater Box Heater Box To provide accurate assessment of Infant colour and sufficient illumination during procedures. Essential Attachments Control Modes: Skin / Air / Manual. Range: Skin control: 34 to 38 ˚C Air control: Room temp. to 39˚ C" Resolution: 0.1˚ C Accuracy: ± 0.2˚ C Display: 1” bright skin & air temp.(7 segment LED) % of heater output (bar graph)" Status: On LED Timer: Timer / APGAR Timer/Baby Attend Manual mode: Time Programmable Heater output settable Over temp. cut-off Alarm: Auto audio alarm mute, Mute time programmable Safety alarms: ON LED The mentioned are default limit, can be set or alter as per requirement:
- Skin Low 0.5˚C - Under range (<34˚C) - Over range (>38˚C) - Low 3.0˚C - Over range |
NIC691 - Infant Radiant Warmer with Detachable Baby Cradle & Drawers (Premium) with Microprocessor based temprature controller with 2 modes Skin / Manual mode
This is mobile Warmer mounted on wheels with fixed baby cradle.
Mechanical Specification Heater Box Heater Box To provide accurate assessment of Infant colour and sufficient illumination during procedures. Essential Attachments Control Modes: Skin / Manual. Range: Skin control: 34 to 38 ˚C Resolution: 0.1˚ C Accuracy: ± 0.2˚ C Display: 1” bright skin & air temp.(7 segment LED) % of heater output (bar graph)" Status: On LED Timer: Timer / APGAR Manual mode: Time Programmable Heater output settable Over temp. cut-off Alarm: Auto audio alarm mute, Mute time programmable Safety alarms: ON LED The mentioned are default limit, can be set or alter as per requirement:
|
NIC690 - Infant Radiant Warmer with Detachable Baby Cradle & Drawers (Premium) with Microprocessor based temprature controller with 3 modes Skin /Air / Manual mode
This is mobile Warmer mounted on wheels with fixed baby cradle.
Mechanical Specification Heater Box Heater Box To provide accurate assessment of Infant colour and sufficient illumination during procedures. Essential Attachments Control Modes: Skin / Manual. Range: Skin control: 34 to 38 ˚C Air control: Room temp. to 39˚ C". Resolution: 0.1˚ C Accuracy: ± 0.2˚ C Display: 1” bright skin & air temp.(7 segment LED) % of heater output (bar graph)" Status: On LED Timer: Timer / APGAR Timer/Baby Attend Manual mode: Time Programmable Heater output settable Over temp. cut-off Alarm: Auto audio alarm mute, Mute time programmable Safety alarms: ON LED The mentioned are default limit, can be set or alter as per requirement:
- Skin Low 0.5˚C - Under range (<34˚C) - Over range (>38˚C) - Low 3.0˚C - Over range |
NIC621 - Infant Radiant Warmer with Fixed Baby Cradle & Drawers (Standard) with Microprocessor based temprature controller with 2 modes Skin / Manual mode
These are mobile Warmer mounted on wheels with fixed baby cradle, lower shelf and 3 drawers storage Cabinet.
Technical Specification Heater Box To provide accurate assessment of Infant colour and sufficient illumination during procedures. Baby Tray (Stainless Steel) For Skin / Manual mode, following are the feature: Control Modes: Skin / Manual. Range: Skin control: 34 to 38 ˚C Resolution: 0.1˚ C Accuracy: ± 0.2˚ C Display: 1” bright skin & air temp.(7 segment LED) % of heater output (bar graph)" Status: On LED Timer: Timer / APGAR Manual mode: Time Programmable Heater output settable Over temp. cut-off Alarm: Auto audio alarm mute, Mute time programmable Safety alarms: ON LED The mentioned are default limit, can be set or alter as per requirement:
|
NIC620 - Infant Radiant Warmer with Fixed Baby Cradle & Drawers (Standard) with Microprocessor based temprature controller with 3 modes Skin / Air / Manual mode
These are mobile Warmer mounted on wheels with fixed baby cradle, lower shelf and 3 drawers storage Cabinet.
Technical Specification Heater Box To provide accurate assessment of Infant colour and sufficient illumination during procedures. Baby Tray (Stainless Steel) For Skin / Air / Manual mode, following are the feature: Control Modes: Skin / Air / Manual. Range:Skin control: 34 to 38 ˚C Air control: Room temp. to 39˚ C" Resolution: 0.1˚ C Accuracy: ± 0.2˚ C Display: 1” bright skin & air temp.(7 segment LED) % of heater output (bar graph)" Status: On LED Timer: Timer / APGAR Timer/Baby Attend Manual mode: Time Programmable Heater output settable Over temp. cut-off Alarm: Auto audio alarm mute, Mute time programmable Safety alarms: ON LED The mentioned are default limit, can be set or alter as per requirement:
- Skin Low 0.5˚C - Under range (<34˚C) - Over range (>38˚C) - Low 3.0˚C - Over range |
1 2 next