ECG Machine
Cliquez ici pour modifier.
ECG-1200G Digital 12 Channel ECG
Features:
- Lead: Standard 12 leads
- Patient leak current: <10uA
- Input impedance: >=50M
- Frequency response: 0.05 ~ 150HZ(-3dB)
- Time constant: >3.2S
- CMRR: >100dB
- Dimention of recording paper: 80mmx20m
- Paper speed: 25mm/s, 50mm/s
- Sensitivity choice: 5, 10,20mm/mV.
- Measurement parameters: HR, P-R interval, P-Duration, QRS Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
- 8" TFT display, 800x600 pixels. led backlight
- Simultaneous 12 leads acquisition and display
- Digital signal process technique, AC filter, baseline filter, EMG filteretc.
- Auto-analysis and auto-interpretation
- Multi-mode display and printing, such as12, 6+1(rhythm), 6, rhythm 12, rhythm10, rhythm 8, rhythm 6, Manual, Freeze etc.
- Multi-language options: Germany, France, Italian, Turkey, etc
- Built-in lithium rechargeable battery,
- USB and LAN socket for uploading data to PC
- Memory: Built-in flash memory . Store more than 1000 pieces of archive
- Product safety type: Class I, CF. Defibrillation and pacing protection
- Enduring polarization voltage: ±300mv
- Nosie level: <15uVp-p
- Dimension: 340mm(L) ×320mm(W)× 80mm(H)
- Net wight: 3.5KG
- Navigating options: mouse, keyboard, touchscreen
- Other options: Wireless LAN.
ECG-1200F Digital 12 Channel ECG
Feature
- 7" TFT, touch screen, led backlight
- Digital isolation technology and signal pro-cessing solution, digital filter
- Patient managment, name and age and id.
- Detail analysis report.
- Multi-language options: Germany, France, Italian, Turkey, etc
- Built-in lithium rechargeable battery, wide thermall printing system
- USB and LAN socket.
- Memory: Built-in memory or mini SD Memory card. Store more than 1000 pieces of archive
- Auto-measurement, auto-analysis, and auto-interpretation.
- Lead: Standard 12 leads
- Patient leak current: <10uA
- Input impedance: >=50M
- Frequency response:0.05 ~ 150HZ(-3dB)
- Time constant:>3.2S
- CMRR:>100dB
- Dimention of recording paper: 80mmx20m
- Paper speed: 25mm/s, 50mm/s
- Sensitivity choice:5, 10, 20mm/mV.
- Measurement parameters:HR, P-R interval, P-Duration, QRS Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
- Product safety type: Class I, CF. Defibrillation and pacing protection
- Enduring polarization voltage: ± 300mv
- Nosie level: <15uVp-p
- Dimension: 130mm(L)× 74mm(W)× 25mm(H)
- Net wight: 2.3KG
ECG-300 Digital 3 Channel ECG
Feature
- High resolution thermal printing system ,high precision
- 12 leads collection in phase as well as 3 leads printing in phase
- Digital design and filter, baseline auto-adjustable.
- LCD displays operation menu .DC/AC auto-exchange
- Automatic measurement ,analysis and diagnosis with high speed
- Elegant and compact outlook, with inner handhold.
ECG-1200F Digital 12 Channel ECG
Feature
- 12 Lead ECG simultaneous acquisition, simultaneous display of3/6/12lead ECG waveform
- Build-in real-time analysis software, average QRS template
- RS232 and USB interface
- Multiform printing modes and format:Auto/Manual, standard 12 Ch,3Ch+3R, 6Ch,6Ch+1R and 60s arrhythmia report.
- Physical examination mode (A4 Paper), R-R histogram, trend, average QRS template
- Build-in SD Card
- Input way: Floating and defibrillation protection
- Lead: Standard 12 leads
- Input impedance: ≥50MΩ
- Frequency response: 0.05Hz~150Hz(-3dB,+0.4dB)
- Time constant: >3.2s
- Noise level: ≤13μVp-p
- Filter: AC filter, ECG interference filter, DFT filter
- Sensitivity: Auto 10,20mm/mV±2% ect
- Measure date: HR, interval, Duration, Axis
- Paper speed: 25,50mm/s,±%3 ect
- Recording paper: 210/216mm(W)x20/30m(L)
- Safety Type: Class I,Typbu xinge CF
- Size: 338mm(L)x280MM(w)85MM(h)
- Net Weight: 3.5Kg
- ECG Workstation Software
- SD Card
- Portable Pack
- Trolley
- 7"LCD B/W, Color, Touch
ECG 1200B Digital 12 Cannel ECG
Specification
- Input Circuit: Floating; Protection against Defibrillator effect
- Lead: Standard 12 leads, Lead change automatically
- Patient Current Leakage: <10 μ A
- Input Impedance: ≥50 ΜΩ
- Calibrating Voltage: 1mV ±3%
- A/D Conversion: 12 bit
- Display: 320×240LCD
- Frequency Response: 0.05Hz-150Hz
- Time Constant: >3.2seconds
- CMRR: >80d>100dB(with filter)
- Paper Speed: 25, 50mm/s±3%
- Recording Paper: 210mm×30m, Roll paper
- Input Circuit Current: ≤50nA
- Safety Standard: IEC class I, type CF
- Sensitivity: 1/2, 1, 2(cm/mV)
- Skin Voltage Tolerance: ±300mV
- Noise Level: <15 μVp-p
- Weight: 5.1kg
- Simultaneous 12 leads acquisition and printing
- Automatic measurement and interpretation; R-R analysis
- 12 leads simultaneous display on large backlight LCD 320×240
- Digital design and filter ; Thermal array printer
- Baseline auto-adjustable; Rhythm lead selectable
- DC/AC auto exchange, built-in rechargeable battery. Power supports continuously working for more than 50 patients
ECG-1200A Digital 12 Channel ECG
- Input Circuit : Floating; Protection against Defibrillator effect
- Lead: Standard 12 leads ,Lead change automatically
- Patient Current Leakage:<10 μ A
- Input Impedance:≥50 ΜΩ
- Calibrating Voltage: 1mV ±3%
- A/D Conversion:12 bit
- Display:320×240LCD
- Frequency Response:0.05Hz-150Hz
- Time Constant:>3.2seconds
- CMRR:>80d>100dB(with filter)
- Paper Speed:25,50mm/s±3%
- Recording Paper: 210mm×30m, A4 size
- Input Circuit Current: ≤50nA
- Safety Standard: IEC class I, type CF
- Sensitivity: 1/2,1,2(cm/mV)
- Skin Voltage Tolerance: ±300mV
- Noise Level:<15 μVp-p
- Weight: 5.1kg
- Simultaneous 12 leads acquisition and printing
- Automatic measurement and interpretation;R-R analysis
- 12 leads simultaneous display on large backlight LCD 320×240
- Digital design and filter ; Thermal array printer
- Recording on A4 size paper
- Baseline auto-adjustable; Rhythm lead selectable
- DC/AC auto exchange, built-in rechargeable battery. Power supports continuously working for more than 50 patients
- 16 pieces of unzipped ECG date and waveforms are stored for copy and re-call
- Inner handhold designed for portability
NML-80B-Hand Held Single Channel ECG
Technical Parameters
- Input circuit: Floating
- Calibrating Voltage: 1mV ?%
- Input current: <100nA
- CMRR: >103dB
- A/D: 12bit
- Frequency Response: 0.05Hz--150Hz
- Filter: AC 50/60Hz EMG: 35-4Hz
- Skin Voltage Tolerance: ?00mV
- Sensitivity Setting 5, 10, 20mm/mV, conversion deviation?%
- Noisy Level: ?5Vp-p
- Safety standard: IEC class I, type CF
- Lead selection: Automatic and Manual
- Operation mode: Automatic and Manual Display: LCD 160*96 visual size: 34*60
- Recording system: Thermal-array printing
- Power supply: AC220V?0% DC 7.4 lithium battery
- Size: 190*90*40
- Weight: About 800g
ECG-300G Digital 3 Channel ECG
Features
- High resolution thermal printing system, high precision
- 12 leads collection in phase as well as 3 leads printing in phase
- Digital design and filter, baseline auto-adjustable.
- LCD displays operation menu. DC/AC auto-exchange
- Automatic measurement, analysis and diagnosis with high speed
- Elegant and compact outlook, with inner handhold.
NML-80A-Hand Held Single Channel ECG
Technical Parameters
- Input circuit: Floating
- Calibrating Voltage :1mV ?%
- Input current: <100nA
- CMRR: >103dB
- A/D: 12bit
- Frequency Response: 0.05Hz--150Hz
- Filter: AC 50/60Hz EMG: 35-4Hz
- Skin Voltage Tolerance: ?00mV
- Sensitivity Setting 5, 10, 20mm/mV, conversion deviation?%
- Noisy Level: ?5Vp-p
- Safety standard: IEC class I, type CF
- Lead selection: Automatic and Manual
- Operation mode: Automatic and Manual
- Display: LCD 160*96 visual size: 34*60
- Recording system: Thermal-array printing
- Power supply: AC220V?0% DC 7.4 lithium battery
- Size:190*90*40
- Weight: About 800g
ECG-100G Digital Single Channel ECG
Features:
- High-resolution thermal printing array system/li>
- Frequency response is as high as 150Hz/li>
- Capable of printing continuously on channel trace and annotations including lead mark and parameter such as sensitivity, paper speed and filter operation status
- High resolution digital filter inhibits baseline drift without affecting ECG waveform
- One-touch operation
- Concept of floating input circuit meets IEC safety standard
- Rechargeable battery supporting more than 50 patient examinations
- Lead Standard: 12 leads